Time synchronization is an important aspect for all computers on the network. By default, the clients computers get their time from a Domain Controller and the Domain Controller gets his time from the domain’s PDC Operation Master. Therefore the PDC must synchronize his time from an external source. I usually use the servers listed at the NTP Pool Project website. Before you begin, don’t forget to open the default UDP 123 port (in- and outbound) on your firewall. 

  1. First, locate your PDC Server. Open the command prompt and type: C:\>netdom /query fsmo
  2. Log in to your PDC Server and open the command prompt.
  3. Stop the W32Time service: C:\>net stop w32time
  4. Configure the external time sources, type: C:\> w32tm /config /syncfromflags:manual /manualpeerlist:time.windows.com
  5. Make your PDC a reliable time source for the clients. Type:C:\>w32tm /config /reliable:yes
  6. Start the w32time service: C:\>net start w32time
  7. The windows time service should begin synchronizing the time. You can check the external NTP servers in the time configuration by typing: C:\>w32tm /query /configuration
  8. Check the Event Viewer for any errors.

Tested on Windows Server 2008 R2 (Build 7600).